Infinite F50 Absorbance Reader

The Infinite F50 and Infinite F50 Robotic absorbance plate readers, together with Magellan data analysis software, are ideal solutions for photometric measurements of ELISAs and kinetic assays in the 400 to 750 nm wavelength range. The systems’ innovative design combines eight measurement channels with long-life LED lamps for fast parallel reading and minimal maintenance costs.

Available in ROI/NI

Features

  • Versatility In a Small Footprint

Benefits

  • Deal for absorbance-based ELISAs, kinetic and multi-label reading
  • Ready for qualitative and quantitative data analysis using Magellan data analysis software
  • All major curve fittings supported

Highlights

  • Reader-operated front door for easy plate loading
  • The reader’s housing can be partially removed during set-up, providing full access to the plate carrier for more straightforward teaching of the robotic arm
  • Ready for integration onto Tecan’s Freedom® EVOand Fluent® platform

Add-On Tools

LIS option

The hand-held barcode scanner included in the LIS option is a time-saving and convenient tool for reading barcoded sample or plate IDs.

It provides automated data transfer into Magellan software and data export to a LIS in ASCII and ASTM formats.

 

Additional filters

The standard filter configuration of the Infinite® F50 and Infinite F50 Robotic plate readers enables absorbance measurements at 405, 450, 492 and 620 nm.

Additional filters are available separately.

 

MultiCheck™ QC package and IQOQ services

The MultiCheck QC package for the Infinite F50 and Infinite F50 Robotic plate readers offers a fast and easy way to verify and document reliable instrument functionality over time.

The MultiCheck QC package provides an appropriate system check for installation qualification (IQ) and operational qualification (OQ).

The following key reader parameters are verified according to pass/fail criteria

  • Accuracy
  • Precision
  • Linearity
  • Plate carrier alignment
  • Positioning check of standard filters

Specifictions

 

General  
Detection mode Absorbance
Light Source LED, Self-calibrating
Photodetector Silicon photodiodes
Plate Type 96-well microplates (including strip-well)
Shaking Linear shaking in 4 different modes
Interface USB
   
Measurement Modes  
Measurement Modes Endpoint, kinetic & multilabel
Measurement channels 8
Reference channel 1
Measurement range 0-4 OD
Resolution 0.0001 OD
   
Wavelength range  
Wavelength range 400-750nm
Wavelength selection Upto 8 filters on wheel
   
Accuracy at 450/492nm  
0.000-2.000 OD ≤(0.5 % + 0.010 OD) typical
2.000-3.000 OD ≤(1 % + 0.010 OD) typical
   
Precision at 450/492nm  
0.000-2.000 OD ≤(0.5 % + 0.005 OD)
2.000-3.000 OD ≤(1 % + 0.005 OD)
   
Linearity  
0.000-2.000 OD ≤1.0%
2.000-3.000 OD ≤1.5%